RL Time Constant Calculator
Find the time constant of an RL circuit.
Result
How it is calculated
In a series RL circuit the time constant is τ = L / R, where L is the inductance in henries and R the resistance in ohms; the result is in seconds. The tool also shows it in milliseconds, τ × 1000. After one τ the current has risen to about 63% of its final value when a voltage is applied, and after about five τ it is practically at its final value. Resistance must be above zero; inductance may be zero or more. The seconds value is shown with six decimals and the milliseconds value with four, so very small constants are not rounded away. R is the total series resistance, including the coil's own winding resistance.
Worked example
A coil of L = 0.05 H (50 mH) is in series with R = 100 Ω. τ = 0.05 / 100 = 0.0005 s. In milliseconds that is 0.0005 × 1000 = 0.5 ms. The time constant is 0.000500 s, or 0.5000 ms. The current needs roughly 5 × 0.5 = 2.5 ms to settle close to its final value.
Common mistakes
- Entering inductance in millihenries (50) while the field expects henries (0.05), making τ a thousand times too large.
- Entering resistance in kilohms without converting to ohms.
- Forgetting the coil's own resistance or the source resistance, which add to R in the circuit.
- Using this formula for an RC circuit. That one is τ = R × C, not L / R.
- Expecting the current to reach its final value after exactly one τ; one τ is only about 63%.
About this calculator
The time constant of an RL (resistor-inductor) circuit is τ = L/R, where L is inductance and R is resistance. It defines how quickly current rises or decays in the circuit: after one time constant, current reaches about 63.2% of its final value; after five time constants, it's essentially fully settled (>99%) — the same exponential charging pattern seen in RC circuits, but governed by inductance instead of capacitance.
Electrical engineers use the RL time constant to predict switching behavior in circuits with inductive loads — relays, solenoids, motor windings, and transformer coils — where a sudden current interruption can generate a damaging voltage spike, which is why techniques like flyback diodes are sized with this time constant in mind. Enter L and R to get τ.
Was this helpful?
You can pick up to 3 reactions.
Popular calculators
Loan Calculator
Monthly payment, total interest and full amortization schedule.
Percentage Calculator
Percent change, percent of, and ratio calculations.
Discount Calculator
Calculate final price, savings, and discount amount.
BMI Calculator
Body mass index from height and weight (metric or imperial).
Age Calculator
Compute your exact age in years, months and days from a birth date.
Compound Interest Calculator
Calculate the final amount and interest earned with compounding.
All Calculators
No calculators found
Comments (0)