Wet-Bulb Temperature Calculator
Find the wet-bulb temperature to gauge heat stress and cooling potential.
Result
How it is calculated
Enter the air temperature in degrees Celsius and relative humidity as a percentage (0 to 100). The tool applies Stull's 2011 empirical approximation, with T the air temperature and RH the humidity:
Tw = T·atan(0.151977·√(RH + 8.313659)) + atan(T + RH) − atan(RH − 1.676331) + 0.00391838·RH1.5·atan(0.023101·RH) − 4.686035
The angles are in radians. The Fahrenheit value is Tw × 9/5 + 32. Both are rounded to two decimals. Humidity outside 0 to 100 gives no result. This is a fitted approximation, not a full psychrometric calculation, and it ignores air pressure; at 100% humidity it can come out a fraction of a degree above the air temperature.
Worked example
Air at 30 °C and 70% humidity. The four terms are: 30 × atan(0.151977 × √78.31) = 27.943; atan(100) = 1.561; atan(68.32) = 1.556, which is subtracted; and 0.00391838 × 701.5 × atan(1.617) = 2.334. Adding and subtracting, then taking off 4.686, gives a wet-bulb temperature of 25.60 °C, or 25.60 × 9/5 + 32 = 78.07 °F.
Common mistakes
- Entering the temperature in Fahrenheit; the formula needs Celsius, and the Fahrenheit figure is only an output.
- Typing humidity as a fraction such as 0.7 instead of 70, which gives a wildly different (and much lower) result.
- Confusing wet-bulb with the heat index or feels-like temperature; they are different measures built from different formulas.
- Using the dew point where relative humidity is asked for.
- Reading the result as exact: the formula is an approximation and ignores pressure, so a measured wet-bulb reading with a psychrometer may differ slightly.
About this calculator
This calculator estimates wet-bulb temperature (Tw) from air temperature and relative humidity using Stull's formula, an arctangent-based empirical approximation from 2011 that's accurate to within about 0.3°C for typical conditions without needing a psychrometric chart. Wet-bulb temperature reflects the lowest temperature achievable through evaporative cooling.
Meteorologists, occupational health officers, and outdoor-event organizers use it to gauge heat stress risk — wet-bulb readings above roughly 32°C (90°F) signal dangerous conditions where sweat can no longer cool the body effectively. Enter the air temperature and relative humidity to get the wet-bulb temperature.
Was this helpful?
You can pick up to 3 reactions.
Popular calculators
Loan Calculator
Monthly payment, total interest and full amortization schedule.
Percentage Calculator
Percent change, percent of, and ratio calculations.
Discount Calculator
Calculate final price, savings, and discount amount.
BMI Calculator
Body mass index from height and weight (metric or imperial).
Age Calculator
Compute your exact age in years, months and days from a birth date.
Compound Interest Calculator
Calculate the final amount and interest earned with compounding.
All Calculators
No calculators found
Comments (0)